Sdc S6100 SERIES REVERSIBLE PANIC/FIRE EXIT Manual de usuario Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
3. Adjustment procedure:
Adjust the length of the two vertical rods by hand through the cut-outs (figure 4-2).
Shorten or lengthen the rods by turning into or out of the latch assemblies (figure 4-3)
until the holes of the shaft connectors are in the proper position as determined by the
latch length locator (pg. 5, figure 4-1).
P:\INSTALLATION INST\Mechanical Hardware\INST-S6800.vsd Rev - 12/10 Page 6
E. INSTALL LATCH ACTUATOR SHAFTS
1. Attach one Latch Actuated Shaft to the top and bottom shaft
connectors (figure 5) with screws supplied.
2. Make sure both top and bottom latch actuated shafts are parallel.
F. INSTALL DEVICE AND TRIM (if applicable)
1. Remove device chassis cover from the chassis assembly and the
end cap from the end cap bracket.
2. Position the device on the door and insert latch actuated shafts into
the slots marked “X” and “Y” (figure 6-1). Fasten in place with
screws supplied.
Figure 4-2
Figure 4-3
Figure 5
Latch Actuated
Shaft
Figure 6-1
X
Y
Vista de pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23

Comentarios a estos manuales

Sin comentarios