P:\INSTALLATION INST\Mechanical Hardware\INST-S6800.vsd Rev - 12/10 Page 3
A. PREPARE DOOR
1. Mark centerline of device by
drawing a line across the door.
2. Mark a backset line and 4 thru
holes for device chassis shown
on the template provided.
3. Prepare the door cut-outs by
using the template provided.
Figure 1-2
4. Cut out the top edge and bottom edge of the door, then weld two 5mm thick mounting plates
on both edges for Top and Bottom Latch Assemblies (figure 1-2).
5. Drill holes and use a #10-24 tap on the mounting plates on the top and bottom of door.
The centerline of the
device must be 40"
above the finished
floor. Bottom Door
gap MUST be 1/4”.
2-7/16"
of Device
L
C
Mark backset from edge of door
INSIDE FACE OF DOOR
Drill holes and
cut-outs on the
Device side ONLY
of Device
L
C
3
9
-
3
/
4
See Trim Installation
Instructions for outside
face of door preparation.
Figure 1-1
1-3/4”
2-1/4”
7/8"
2-7/16”
1-19/32"
1-9/32"
1-5/32"
23/32"
1-11/16"
7/16"
7/8"
7/8"
Inside Face
of Door
1-17/32"
Vista de pagina 14