WARNING!
CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL
PRIOR TO SELECTING DELAY TIME OR PWR-UP SETTINGS
101-DE
101-KDE
PWR LOCK RED R
NO C
TRIG REX RESET
C NOC NOC NO- +- +
To
Power
Supply
TANDEM UNIT
(PAIR OF DOORS)
WHT
WHT
BLK
RED
WHT
WHT
BLK
RED
POWER
TRANSFER
HINGE
POWER
TRANSFER
HINGE
DPS
DPS
SDC 600 Series Power Supply required
**
DIP SWITCH
SETTINGS
15
30
1
2
15 20 30 1
N/CN/O
UNLOCKED LOCKED
VOICE/TONE
TONE
ONLY
FEMALE
MSG
MALE
MSG
ON
DELAY
TIME
[ON]
[OFF]
1 2 3 4 5 6 7 8
NUISANCE
DELAY
REX/BYPASS
PERIOD
TRIGGER
TYPE
PWR UP
STATE
ALARM
TYPE
MESSAGE
JUMPER J1**
24VDC @ 430mA (Single)
@ 680mA (Tandem)
Monitor Relays
Contact Rating
Operating Temp
Range
Power
Requirements
SPDT (Dry)
1 Amp @12/24VDC (Resistive)
0 C to 70 C
Note:
**JUMPER J1 (DOOR PROP)
INSTALLED: The S6000DE/KDE will enter the alarm mode if the
door is held open past the request to exit period.
REMOVED: The S6000DE/KDE will remain unlocked if the door
is held open past the request to exit period. No alarm will sound.
For the S6000DE/KDE to relock and rearm upon closure of the
door, DPS is required.
Door Contact or Power Transfer Hinge by DPS required for Anti-
Tailgate and Door Prop operation.
**
**
To
Power
Supply
101-DE / 101-KDE
PWR
LOCK
RED ONLY
NO C
TRIG REX RESET
C NOC NOC NO
- +- +
GRN ONLY
WHT
WHT
BLK
RED
POWER
TRANSFER
HINGE
SINGLE
DOOR
DPS
**
}
}
Alarm Secure
}
}
Remote
Access
Remote
Reset
Monitor Relays
P:\INSTALLATION INST\Delayed Egress\INST-S6000DE_KDE_MOD.vsd Rev -2 08-12 Page 4